Fire Door Inspections are required annually per the 6th Edition (2017), Florida Fire Prevention Code and Chapter 36 of the 6th Edition (2017), Florida Building Code. The inspection guidelines are incorporated via reference to NFPA 80, Standard for Fire Doors and Other Opening Protectives, 2013 Edition and NFPA 101 – Life Safety Code. NFPA 80 stipulates all fire door assemblies must be inspected annually and a written record retained (Chapter 8). Note: As of 2021, the FBC has not adopted a later version of NFPA 80 contrary to what some inspection companies are claiming.
NFPA 80 (2013 Edition) requires fire doors, fire shutters and fire window assemblies to be inspected and tested upon completion of their installation and also upon completion of any maintenance or alteration work as well as annually.
Many building owners/facility managers are confused on fire door inspections. Many simply do not order inspections. Enforcement of inspections is typically delegated to the local Fire Marshall/fire department. Fire Marshall inspections are often only conducted during initial occupancy or upon change of occupancy. Budget and staffing restraints generally do not allow annual inspections, so fire door inspections are often overlooked but that does not mean the building owner is not required to complete the inspections. Health care facilities subject to funding from the Centers for Medicare and Medicaid Services (CMS) must conduct and document fire door assembly inspections since 2016.
Adherence to Life Safety Codes is a legal responsibility to building owners and facility managers and, in the event, a malfunctioning fire door resulted in injury or death to an occupant, you may be subject to personal injury claims which may pierce the corporate veil. Trying to save a few dollars by taking advantage of lax oversight could be a significant mistake.
Buildings are not “grandfathered” due to age or location. Any building which is open to public use requires annual inspections of fire rated doors.
NFPA 80 undergoes constant updates but adoption by the Florida Building Code typically lags behind. The latest FBC incorporates the 2013 version of NFPA 80.
A basic fire door assembly inspection will include:
Property360 provides fire door assembly inspections for any type of facility in the Jacksonville, FL area. Our client base includes hospitals, medical facilities, industrial and warehousing, retail, office buildings, schools, assisted living and retirement centers, condominiums, hospitality and entertainment venues.
Contact us today at (904) 503-9808 for a free estimate.
Let’s face it – AC systems are expensive to repair and replace but they are…
Buying or building a home in Baker County, Florida can be challenging. There is not…
Spring has arrived and Jacksonville homeowners should start preparing their homes for the summer storm…
The team at Property360 has come up with a list of our favorite tips and…
There are benefits to having your air ducts cleaned, although it depends on several underlying…
There are two primary reasons your insurance carrier may deny your claim: You declined the…